E
XPANDER
23
Talkback and Intercom System
V12 consoles include both a “Closed Loop” talkback system and an
industry standard intercom system. The closed loop system allows for
private communications between two Crest console operators including
the ability of the “external” talkback input to have selectable access
to all of the consoles talkback outputs and “Hot Access” to the
engineering monitor and headphone systems.
Meter Switch Bank
Interlocking switch selects assignment for the single bank of 8 meters on
the SideCar meter bridge. When used with a master console, these
meters may be selected to monitor the master console or local functions.
Aux Masters 1- 8
Allows local access and output of Aux buses 1-8. Iso switch isolates
(breaks) Aux bus connection between SideCar and master console.
VCA Local Control
Removes master console control of VCA channels 1-4, allowing use in
stand-alone applications or effectively adding 4 VCA groups when used
in linked applications.
Local L/R and Mono Output Sections
Individual 100mm high quality faders, local Solo and Mute controls, Iso
Sys Switch (isolates the Left, Right, and Mono bus connection between
the SideCar and master console), and assignment for local Sum output.
Solo Mode Section
Selects Additive, “Last Pressed” (Interlock) or Momentary modes, and
AFL or PFL local Solo.
SideCar Expander
The comprehensive facilities on the V12 SideCar expander allow opera-
tion as a self-standing console as well as adding inputs and flexibility
when linked to a V12 master. Most functions are similar to counterparts
on the main V12, but some are worthy of note.